Welcome to Beijing Gallop Technology Co., Ltd
Hotline:010-82783112
Products

26G RADAR LEVEL METER


GRD98 series sensors are 26GHZ radar level meters, maximum measuring distance is 70 meters. Antenna is optimizated, new rapid microprocessor can undertake higher rate of signal analysis and processing, make the instrument can be used in the reaction kettle, some complex measuring conditions, such as solid bin.



981.jpg

APPLICATIONVarious corrosion fluid

RANGE20 m

PROCESS CONNECTIONThread, Flange

TEMPERATURE- 40 ~120 

PRESSURE-0.1 ~ 0.3 MPa

ACCURACY±5mm

PROTECTIONIP67

FREQUENCY26 GHZ

EXPLOSION  LEVEL  Exd C T6 Gb

OUTPUT4 ~ 20 mA/HART (two lines/four lines)    RS485 / Modbus                                

GRD981


982.jpg

APPLICATIONHeat resistance, pressure, slight corrosion fluid

RANGE30 m

PROCESS CONNECTIONThread, Flange

TEMPERATURE- 40 ~250 

PRESSURE-0.1 ~ 4.0 MPa

ACCURACY±3 mm

PROTECTIONIP67

FREQUENCY26 GHZ

EXPLOSION  LEVEL  Exd C T6 Gb

OUTPUT4 ~ 20 mA/HART (two lines/four lines)RS485/Modbus

GRD982


983.jpg

APPLICATIONsolid material, strong dust, easy to 

                               crystallization, condensation

RANGE70 m

PROCESS CONNECTIONuniversal flange

TEMPERATURE- 40 ~250

PRESSURE-0.1 ~ 0.3 MPa

ACCURACY± 15 mm

PROTECTIONIP67

FREQUENCY26 GHZ

EXPLOSION  LEVEL Exd C T6 Gb

OUTPUT4 ~ 20 mA/HART (two lines/four lines)RS485 / Modbus


GRD983



984.jpg

APPLICATIONsolid material, strong dust, 

                              easy to crystallization, condensation.

RANGE70 m

PROCESS CONNECTIONThread, Flange

TEMPERATURE- 40 ~250

PRESSURE-0.1 ~ 0.3 MPa

ACCURACY±15 mm

PROTECTIONIP67

FREQUENCY26 GHZ

EXPLOSION  LEVEL Exd C T6 Gb

OUTPUT4 ~ 20 mA/HART (two lines/four lines)RS485 / Modbus

GRD984



985.jpg

APPLICATIONSolid particles, powder.

RANGEliquid 30m , powder 20m , dust 15m .

PROCESS CONNECTIONThread, Flange

TEMPERATURE- 40 ~250 

PRESSURE-0.1 ~ 4.0 MPa ( flat flange )

                       -0.1 ~ 0.3 MPa( universal flange )

ACCURACY±10 mm

PROTECTIONIP67

FREQUENCY26 GHZ

EXPLOSION  LEVEL  Exd C T6 Gb

OUTPUT4 ~ 20 mA/HART (two lines/four lines) RS485 / Modbus                                        

                                    

GRD985



986.jpg

APPLICATIONHealth type liquid storage containers,

                              highly corrosive container.

RANGE20 m

PROCESS CONNECTION Flange

TEMPERATURE- 40 ~150  

PRESSURE-0.1 ~ 0.3 MPa

ACCURACY±3 mm

PROTECTIONIP67

 FREQUENCY26 GHZ

EXPLOSION  LEVEL  Exd C T6 Gb

OUTPUT4 ~ 20 mA/HART (two lines/four lines)RS485 / Modbus


GRD986